Model Details | |
Model Number | SCG-BTM-TRML600 |
Product Name | Automatic Body Temperature Measurement and Screening System |
Visible | |
Sensor | 1/1.8”, progressive scan, CMOS |
Focus | Manual |
Iris | >F1.6 |
S/N | >52dB |
Defog | Optical and Digital |
Day/Night | IR-cut Filter with auto switch (ICR) |
Minimum Illumination | Color: 0.001Lux(F1.6, AGC ON) |
B/W: 0.0002Lux(F1.6, AGC ON) | |
Video Frame Rate | 1920*1080, Max 30fps |
WDR | 120dB |
OSD | Up to 8 |
SD Card | Micro SD, up to 256GB |
ANR | Supported |
Network Protocol | IPv4, IGMP, ICMP, ARP, TCP, UDP, DHCP, PPPoE, RTP, RTSP, RTCP, DNS, DDNS, NTP, FTP, UPnP, HTTP, HTTPS, SMTP, 802.1x, SNMP, QoS |
Focal Length | 3.8~16mm |
Thermal | |
Sensor | Uncooled Focal Plane Arrays Type |
Pixel | 25μm |
Max Image Size | 384*288 |
Video Frame Rate | >25fps |
NETD | ≤60mk |
Response waveband | 8~14μm |
Focal Length | 18mm |
Iris | F1.0 |
Angle of view | 25°*19° (H*V) |
Detection distance | 3~10 m |
Blackbody | |
Accuracy | ±0.2℃(Single point) |
Stability | ±(0.1~0.2)℃/30min |
Dimension | 135x135x150mm |
Power | 220V AC 50Hz |
Power Consumption | 60W |
Radiation Area | φ70mm |
Temperature Measurement | |
Environment Temperature Range | 16°C~32°C |
Target Range | 32°C~42°C |
Accuracy | ≤±0.3℃ |
Interface | |
Infrared Machine Head | Aviation Plug |
Network Interface | RJ45 |
Function | |
Alarm | Multi abnormal temperature point alarm and automatic capture |
Capture | Capture when alarm is triggered |
Temperature Temperature Display | Simultaneous display: temperature in infrared and visible light images |
Body and Surface Temperature Correction | Supports automatic temperature calibration |
General | |
Power Supply | DC12V |
Power Consumption | ≤15W |
Working Environment | ≤90%RH |
Infrared Machine Head Weight | <5Kg |
Blackbody Weight | <3.5Kg |
PC Requirement | PC Requirement |